C&C Power manufactures a variety of compact telecom DC power distribution panels. Each of the 1RU solutions is listed to UL standards and CSA certified. Distribution options include circuit breakers, GMT style fuses, and fused pullouts. Each panel can be mounted into a 19" or 23" relay rack and requires only 1RU of rack space.

 
1RU GMT Fuse Panel

1RU GMT Fuse Panel

  • More power in less space
  • 175 amp distribution
  • Up to 40 GMT fuses
  • High density 1RU 19" or 23" rack mount
  • Multiple bus bar configurations
  • Listed to UL Standards and CSA certified

Downloads:

Data Sheet
Drawing

 

C&C Power’s CFP-G 1RU GMT Fuse Panel is a fully enclosed, rear access telecom DC power distribution panel that can accommodate up to 40 GMT fuses. The panel will fit into both 19” and 23” relay racks, and takes up only 1RU (1.75”) of rack space.

The CFP-G distributes up to 150 amps in single bus configurations and up to 300 amps in dual bus configurations. Each bus is equipped with a fuse alarm which includes a set of form C (SPDT) contacts and indicator LED's. Fuse capacities range from less than 1 amp to 15 amps per GMT position, with each 10 position section capable of handling a total of 75 amps maximum.

Other standard features include two hole lug terminations with 1/4-20 studs and 5/8” spacing for DC inputs with up to #2 AWG wire. Each output terminal block accepts bare wire up to #16 AWG or with #6 fork terminal. The 1RU GMT Fuse Panel is listed to UL Standards and is CSA Certified.

 
1RU GMT and TPA Fuse Panel

1RU GMT & TPA Fuse Panel

  • More power in less space
  • 350 amp distribution
  • Up to 20 GMT and 8 TPA fuses
  • High density 1RU 19" or 23" rack mount
  • Multiple bus bar configurations
  • Listed to UL Standards and CSA certified

Downloads:

Data Sheet
Drawing

 

C&C Power’s CFP-GT 1RU GMT & TPA Fuse Panel is a fully enclosed, rear access telecom DC power distribution panel that can accommodate up to 20 GMT and 8 TPA fuses. The panel will fit into both 19” and 23” relay racks, and takes up only 1RU (1.75”) of rack space.

The CFP-GT distributes up to 175 amps in single bus configurations and up to 350 amps in dual bus configurations. Each bus is equipped with a fuse alarm which includes a set of form C (SPDT) contacts and indicator LED's. Fuse capacities range from less than 1 amp to 15 amps per GMT position, with each 10 position section capable of handling a total of 75 amps maximum. TPA fuses range from 3-50 amps.

Other standard features include two hole lug terminations with 1/4-20 studs and 5/8” spacing for DC inputs with up to #2 AWG wire. Each output terminal block accepts bare wire up to #16 AWG for GMT's and up to #6 AWG for TPA's. The 1RU GMT & TPA Fuse Panel is listed to UL Standards and is CSA certified.

 
1RU Telecom Breaker Panel

1RU Telecom Breaker Panel

  • More power in less space
  • 350 amp distribution
  • Up to 12 circuit breaker positions
  • High density 1RU 19" or 23" rack mount
  • Multiple bus bar configurations
  • Listed to UL Standards and CSA certified

Downloads:

Data Sheet
Drawing

 

C&C Power’s CBP-12 1RU Telecom Breaker Panel is a fully enclosed, rear access telecom breaker distribution panel that can accommodate up to twelve flat rocker style breakers. The panel is designed to fit into both 19” and 23” relay racks, and takes up only 1RU (1.75”) of rack space.

The CBP-12 distributes up to 175 amps in the single bus configurations and up to 350 amps in the dual bus configurations. Each bus is equipped with a breaker alarm which includes a set of form C (SPDT) contacts and indicator LED's. Breaker capacities range from 1 amp to 60 amps per position.

Other standard features include two hole lug terminations with 1/4-20 studs and 5/8” spacing for main inputs with up to #2 AWG wire. Each output terminal block accepts bare wire up to #6 AWG. Each panel is listed to UL Standards and is CSA Certified.

 
1RU Control and Distribution Panel

1RU Control and Distribution Panel

 
  • Fully enclosed front access design
  • Commander Plus Series Controller
  • SNMP & web based communication & control
  • Automatic temperature compensation
  • Low voltage load disconnect
  • Dynamic battery string testing with alarm
  • Multiple distribution options available

Downloads:

Data Sheet
Drawing

 

C&C Power’s 1RU Control and Distribution Panel is a fully enclosed telecom DC power system that can accommodate up to two circuit breakers, two fused pullouts, or twenty GMT style fuses for distribution. The maximum system capacity is 175 amps and multiple configurations are available including single or split bus configurations with multiple low voltage load disconnect options.

The Commander Plus Series Controller utilizes a four button keypad to navigate the intuitive menus which are displayed on the easy to read alpha numeric vacuum fluorescent display. This provides a single point of adjustment for all system parameters as well as real time system information and alarms. The Commander Plus Series Controller includes SNMP communication and a web based interface to access system status and adjust system settings.

Other standard features include: automatic adjustment of rectifier output voltage when ambient temperature increases or decreases in order to optimize battery life and performance. An internal circuit breaker main battery disconnect which isolates the attached battery strings for added safety and protection as well as offering an easy means of disconnect for battery maintenance. And an EPO (emergency power off) circuit which allows for remote emergency shutdown of the system. Each system is listed to UL Standards and is CSA certified.

 
 